Product Details

220V single phase diesel generator 15kva

Place of Origin China
Brand Name air-cooled diesel generator
Model Number air-cooled diesel generator
Min.Order Quantity One set 220V single phase diesel generator 15kva
Price [email protected]
Delivery Time Within 5 working days
Payment Terms paypal,UnionPay, Visa/MasterCard, Amex, Discover,T/T
Supply Ability 114

Product Features

220V single phase diesel generator 15kva

1.High thermal efficiency,Low fuel consumption
2.Work reliable, durable
3.Is widely used
4.Lower emissions
5.Good fire safe

Product Description

- Technical Data:

Genset Model(Silent type) CF2-12KVA GF2-25KVA GF2-40KVA GF2-50KVA GF2-60KVA GF2-90KVA GF2-120KVA
Engine Engine Model K4000D K4100D K4100ZD R4105D R4105ZD R6105ZD R6105ZLD
Engine Type Four stroke,Water-cooled,Direct line,Turbo type
Rated Output 10KW / 12.5KVA 20KW / 25KVA 30KW / 37.5KVA 40KW / 50KVA 50KW / 62.5KVA 75KW / 93.75KVA 100KW / 125KVA
Max. Output 12KW/15.0KVA 22KW / 27.5KVA 32.4KW / 40KVA 43KW / 54KVA 53.6KW / 67KVA 77KW / 95.25KVA 105KW / 132KVA
Voltage (V) 380/220
Current (A) 37 37 56 75 94 142 190
Frequency (HZ) 50
Rated RPM (r/min) 1500
Cooling System Forced Water-cooled
Fuel Consumption (≤g/kw.h) ≤258 ≤258 ≤258 ≤231 ≤239 ≤224 ≤224
Compression Ratio 19:01 19:01 17:01 17:01 16:01
Bore×Stroke (mm) 95X115 95X115 100X115 105X125 100X115 105X125 105X130
Displacement (L) 1.63 3.26 3.61 4.33 4.33 6.49 6.75
Start Method Electric Start
Alternator Power Factor 0.8 0.8 Lag
Insulation Class H
Lubricating System Pressure,Split,Complex
Exhaust Air Temperature ≤470 ≤540 ≤600
Altitude ≤1000m
Environment Temperature 40
Connecting Type 3 Phase and 4 Wires,"Y" type connecting
Intake Type Natually-Aspirated pressurize charge inter-cooling
Rated Speed Regulation % ≤±1%
Phase 3
Dimensions Net Weight(kg) 740 770 806 860 890 940 1600
Silent Type's Dimension Length X Width X Height (mm) 1800× 950× 1100 2100× 850× 1240 2150×950×1290 2150×950×1290 2150×950×1290 2700×1100×1560 2700×1100×1560
20FT Loading Quantity 12PCS 6PCS 4PCS 4PCS
Genset Model(Silent type) CF2-12KVA GF2-25KVA GF2-40KVA GF2-50KVA GF2-60KVA GF2-90KVA GF2-120KVA
Engine Engine Model K4000D K4100D K4100ZD R4105D R4105ZD R6105ZD R6105ZLD
Engine Type Four stroke,Water-cooled,Direct line,Turbo type Four stroke,Water-cooled,Direct line,Turbo type Four stroke,Water-cooled,Direct line,Turbo type Four stroke,Water-cooled,Direct line,Turbo type Four stroke,Water-cooled,Direct line,Turbo type Four stroke,Water-cooled,Direct line,Turbo type Four stroke,Water-cooled,Direct line,Turbo type
Rated Output 10KW / 12.5KVA 20KW / 25KVA 30KW / 37.5KVA 40KW / 50KVA 50KW / 62.5KVA 75KW / 93.75KVA 100KW / 125KVA
Max. Output 12KW/15.0KVA 22KW / 27.5KVA 32.4KW / 40KVA 43KW / 54KVA 53.6KW / 67KVA 77KW / 95.25KVA 105KW / 132KVA
Voltage (V) 380/220 380/220 380/220 380/220 380/220 380/220 380/220
Current (A) 37 37 56 75 94 142 190
Frequency (HZ) 50 50 50 50 50 50 50
Rated RPM (r/min) 1500 1500 1500 1500 1500 1500 1500
Cooling System Forced Water-cooled Forced Water-cooled Forced Water-cooled Forced Water-cooled Forced Water-cooled Forced Water-cooled Forced Water-cooled
Fuel Consumption (≤g/kw.h) ≤258 ≤258 ≤258 ≤231 ≤239 ≤224 ≤224
Compression Ratio 19:01 19:01 17:01 17:01 16:01
Bore×Stroke (mm) 95X115 95X115 100X115 105X125 100X115 105X125 105X130
Displacement (L) 1.63 3.26 3.61 4.33 4.33 6.49 6.75
Start Method Electric Start Electric Start Electric Start Electric Start Electric Start Electric Start Electric Start
Alternator Power Factor 0.8 0.8 Lag 0.8 Lag 0.8 Lag 0.8 Lag 0.8 Lag 0.8 Lag
Insulation Class H H H H H H H
Lubricating System Pressure,Split,Complex Pressure,Split,Complex Pressure,Split,Complex Pressure,Split,Complex Pressure,Split,Complex Pressure,Split,Complex Pressure,Split,Complex
Exhaust Air Temperature ≤470 ≤470 ≤540 ≤600 ≤600 ≤600 ≤600
Altitude ≤1000m ≤1000m ≤1000m ≤1000m ≤1000m ≤1000m ≤1000m
Environment Temperature 40 40 40 40 40 40 40
Connecting Type 3 Phase and 4 Wires,"Y" type connecting 3 Phase and 4 Wires,"Y" type connecting 3 Phase and 4 Wires,"Y" type connecting 3 Phase and 4 Wires,"Y" type connecting 3 Phase and 4 Wires,"Y" type connecting 3 Phase and 4 Wires,"Y" type connecting 3 Phase and 4 Wires,"Y" type connecting
Intake Type Natually-Aspirated Natually-Aspirated pressurize pressurize pressurize pressurize charge inter-cooling
Rated Speed Regulation % ≤±1% ≤±1% ≤±1% ≤±1% ≤±1% ≤±1% ≤±1%
Phase 3 3 3 3 3 3 3
Dimensions Net Weight(kg) 740 770 806 860 890 940 1600
Silent Type's Dimension Length X Width X Height (mm) 1800× 950× 1100 2100× 850× 1240 2150×950×1290 2150×950×1290 2150×950×1290 2700×1100×1560 2700×1100×1560
20FT Loading Quantity 12PCS 12PCS 6PCS 6PCS 6PCS 4PCS 4PCS

Tell us your detail requirement, to recommend you the right one

- Features

1. Portable compact open structure
2. Economical, reliable and durable
3. Long run time
4. AVR to automatically regulate voltage
5. Oil alert to shut down engine automatically when low oil is detected
6. Circuit breaker to stop engine automatically when overloaded
7. Powers fridge, furnace, lights, TV, computer, and much more

- Factory Show

CUSTOMERS

The air-cooled diesel generator can have optional wheels and hand kits, Electric start or manual starting.Small-sized diesel generator sets includes open type and silent type.Our 220V single phase diesel generator 15kva adopt different diesel engines and brushless generators.Generally adopt 1-cylinder&4-stroke&air-cooled engine, low fuel consumption, high reliability;It is easy to maintain as adopting brushless A.C.Generator and CDI ignition system.
JHSBJDHV
air-cooled diesel generator are quick-starting, stable-running, little vibration, low noise, light weight, small volume, compact structure, suitable for areas on mining, factory, working on field, engaging in construction and army as movable power or electric power in ship, 220V single phase diesel generator 15kva also suitable for areas on animal husbandry, fishery, forest, orchard, guesthouse and business as standby power.
JSHFDKJ

All Products Contact Now